Ure-Shield U-6006
Single Component Urethane Coating
U-6006
July 2000
Supersedes 12/98

DESCRIPTION:
URE-SHIELD U-6006 is a single component, elastomeric moisture cured urethane elastomeric coating.
USAGE:
This product is designed for use as a general purpose waterproofing coating. It provides weatherability, wear resistance, waterproofing and fire resistance to a variety of surfaces.
COLOR:
Aluminum.
APPLIED COATING DATA
WEATHERABILITY:
Excellent.
CHEMICAL
RESISTANCE:
Good salt and solvent resistance. Fair resistance to acid and alkali.
TENSILE:
ASTM D-412-68

Strength: 1600 psi Min. (11.03 MPa)
Elongation: 400% Min.
Permanent Set at Break: Less than 20%

TEAR
RESISTANCE:
ASTM D-624 Die C 230 Lb/In (41.1 kgm/cm)
HARDNESS, CURED:
ASTM D-676 70 ± 5 Shore A
WATER VAPOR
PERMEABILITY:
ASTM E-96
Method B,100% R.H. Difference
0.02 Perm Inches (.5 mm)
FLAMMABILITY:
ASTM E-108 (UL 790) Class A when applied in accordance with published specifications.
TOXICITY:
Contains flammable solvents and an isocyanate prepolymer. Threshold limit is 100 parts solvent vapor per 1 million parts air. Use only in ventilated areas or with fresh air supplied face masks if in a confined area. Avoid breathing vapors or spray mist. Contains an isocyanate polymer, which may be irritating to the skin or toxic if inhaled. Any material contacting skin should be neutralized by washing with generous quantities of soap and water.
ADHESION:
Excellent adhesion to polyurethane foam, concrete and wood. See primer recommendation chart for other substrates.
PACKAGED PRODUCT DATA
COVERAGE:
Sq. Ft./Gal./Mil. 1065 (26.2 m²/L/.025 mm)
SOLIDS:
Weight:   Method 4041
               Fed. Std. 141
76.4%
Volume: 66.4%
V.O.C.:
287 grams per liter
FLASH
POINT:
ASTM D-56 65º F (19º C)
STORAGE
STABILITY:
One year from date of manufacture when stored in sealed containers below 75ºF (24ºC).
THINNER AND
CLEANER:
T-5116 Regular, T-5130 Spray. Use only thinners supplied by Gaco Western. Thinners from other sources may be contaminated with alcohol which will stop the cure of Ure-Shield U-6006.
APPLICATION
PRIMER:
None required for wood or concrete. Standard sealer system should be used on concrete surfaces other than limited flashing details. Use GacoFlex E-5320 on steel or aluminum, U-5677 on copper and E-2465 on glass and synthetic surfaces.
MIXING:
Mix U-6006 before application to assure uniform color and consistency.

See General Instructions, Section 1A for safety and storage notes.

APPLICATION:
Apply by brush or roller as received. Thinning up to one pint per gallon is permissible if viscosity increases. For spray application, use U-6006 as received. For cold weather application, keep material stored above 65ºF (19ºC).
CLEANUP:
Clean spray equipment with T-5130 thinner. Recirculate through lines and gun until residual U-6006 is removed.
CURE:
Applied coating will cure in 24 hours with 70ºF (21ºC) and 40% relative humidity. Lower temperatures and humidity will require longer times to cure.